2nd Generation Specific 1986-1992 Discussion

88 Rx7 GXL Cranks wont Start HELP

Thread Tools
 
Search this Thread
 
Old 12-02-2005, 05:04 PM
  #1  
Junior Member
Thread Starter
 
kojidean's Avatar
 
Join Date: Dec 2005
Posts: 3
Default

Hey there guys, new to this site. But I heard its the best for rotary questions.

So I have an 1988 Rx7 GXL Cranks wont start. Just got the motor back From atkins rotary who just rebuilt it for me. I have an aftermarket fuel presure regulator whith a gauge, So I know I have enough pressure and fuel flow.Tested it with a HEI spark Tester and have plenty of spark. Have timed it over and over again. Hooked up a code blinker and no codes present. Not sure where to go from here. Any help with be greatly apprciated.



(also starts sometimes but dies right away when I put a bit of ATF in the housing)
kojidean is offline  
Old 12-02-2005, 05:16 PM
  #2  
Senior Member
 
Tessai's Avatar
 
Join Date: Apr 2004
Location: Garland, TX
Posts: 224
Default

When you pull the plugs out, is there fuel on them? Asking because having fuel pressure to the injectors doesn't always mean they are opening properly. Kinda a long shot.



There seems to be mixed opinions on Atkins rebuilds... you may want to give it a compression check and see if it was put together properly? Again, a long shot, but I figure anything you check can't hurt anything .
Tessai is offline  
Old 12-02-2005, 05:20 PM
  #3  
Junior Member
Thread Starter
 
kojidean's Avatar
 
Join Date: Dec 2005
Posts: 3
Default

Yeah, theres fuel when I check the plugs, and I've put a normal comp. checker on there, since I dont have one for Rotarys, But I thought I try anyways. All my readings wre close to each other
kojidean is offline  
Old 12-02-2005, 05:27 PM
  #4  
Senior Member
 
teknics's Avatar
 
Join Date: Dec 2002
Location: Wayne, NJ
Posts: 4,837
Default

they were close but what were the compression numbers?



What is your Fuel Pressure reading?



does it simply crank endlessly? what happens if you give it some gas (press the pedal)



kevin.
teknics is offline  
Old 12-02-2005, 06:00 PM
  #5  
Senior Member
 
matts86fc3s's Avatar
 
Join Date: Oct 2005
Posts: 248
Default

did you check to make sure you put the wires back on it right? leading 1, leading 2, trailing 1, and trailing 2 in the right place... check your afm too if its not connected or broken it wont start
matts86fc3s is offline  
Old 12-04-2005, 12:24 AM
  #6  
Junior Member
Thread Starter
 
kojidean's Avatar
 
Join Date: Dec 2005
Posts: 3
Default

Fuel pressure is 65 psi at KOEO with check wire shorted to energize system, 35psi when cranking. MAF sensor and all other sensors are hooked up correctly and working along with all my plug wires. Cranks easliy enough and sounds like it will almost start up. Floods out if you give it gas. Thanks for input so far, keep it coming.
kojidean is offline  
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
FD_FTW
ECU Discussions
9
11-27-2012 04:00 AM
Volksjager
2nd Generation Specific
4
05-21-2006 08:12 PM
Leetheslacker
2nd Generation Specific
10
05-18-2006 03:33 PM
DJ Blu
2nd Generation Specific
8
06-08-2005 05:36 PM
Streamline
2nd Generation Specific
6
10-15-2002 04:29 PM

Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 