3rd Generation Specific Talk about 3rd gen RX-7's here.

Secondary Injector Upgrades

Thread Tools
 
Search this Thread
 
Old 05-13-2005, 05:17 PM
  #1  
Senior Member
Thread Starter
 
sweet93's Avatar
 
Join Date: Dec 2002
Location: Winston Salem, NC
Posts: 104
Default

I'm in the process of upgrading my secondary injectors but I'm not sure which way to go. I want to go the easiest route. Price isn't to much of a concern at this point.



RC Engineering will enlarge them to 1300cc for $175 each. I called Marren and was told that was the worst thing to do. They would have a bad spray pattern and would no longer be dependable.



Marren recommended going with replacement secondaries, fuel rail and computer system. I'm currently running the Power FC. Any recommendations for injectors and fuel rail that matches up with my computer? What about high and low impedance? Can anybody help me?



Thanks
sweet93 is offline  
Old 05-17-2005, 02:44 AM
  #2  
Senior Member
 
Nospig's Avatar
 
Join Date: May 2005
Posts: 277
Default

Maybe use 850cc secondary injectors in primarys just requires changing o rings so they fit in and seal. In power fc change injector settings from 550 to 850 and lag settings. Ive been told this is good for up to 500 rwhp (using gtr fuel pump and stock lines)
Nospig is offline  
Old 05-17-2005, 06:40 AM
  #3  
Junior Member
 
2turbos's Avatar
 
Join Date: May 2004
Posts: 20
Default

I work at Linder Technical Services.



We shipped several hundreds of thousands of reconditioned fuel injectors last year.

We have tried every way to take an existing design and increase the flow in it.

So far, NOTHING has worked.

1. Spray pattern disrupted

2. Injector output at different pulse widths non-linear

3. Unpredictable fuel flow at different fuel pressures



The best way to increase an injector's flow rate is to replace it with a non-modified

higher flow injector.



If you want to have the flow rate tested of your injectors, check our website at

www.lindertech.com. We do this for free if you send them to my attn.



Send them to my attention at:



Linder Technical Services

Attn: 2turbos

4-D Gasoline Alley

Indianapolis, In 46222



(Yes, It is that Gasoline Alley)
2turbos is offline  
Old 05-17-2005, 10:29 AM
  #4  
Senior Member
 
Midnightdriver's Avatar
 
Join Date: Aug 2002
Location: Reno,NV
Posts: 1,081
Default

just spend the money for a higher flow pump, upgraded fuel rail and 1000cc secondary injectors...don't go cheap. do it only once.
Midnightdriver is offline  
Old 06-11-2005, 10:01 PM
  #5  
Senior Member
Thread Starter
 
sweet93's Avatar
 
Join Date: Dec 2002
Location: Winston Salem, NC
Posts: 104
Default

Thanks for all the help.
sweet93 is offline  
Old 06-12-2005, 05:33 PM
  #6  
Senior Member
 
FikseRxSeven's Avatar
 
Join Date: Jan 2003
Location: union, new jersey
Posts: 8,079
Default

[quote name='2turbos' date='May 17 2005, 06:40 AM']I work at Linder Technical Services.



We shipped several hundreds of thousands of reconditioned fuel injectors last year.

We have tried every way to take an existing design and increase the flow in it.

So far, NOTHING has worked.

1. Spray pattern disrupted

2. Injector output at different pulse widths non-linear

3. Unpredictable fuel flow at different fuel pressures



The best way to increase an injector's flow rate is to replace it with a non-modified

higher flow injector.



If you want to have the flow rate tested of your injectors, check our website at

www.lindertech.com. We do this for free if you send them to my attn.



Send them to my attention at:



Linder Technical Services

Attn: 2turbos

4-D Gasoline Alley

Indianapolis, In 46222



(Yes, It is that Gasoline Alley)

[snapback]714048[/snapback]

[/quote]





you will be this site's new best friend
FikseRxSeven is offline  
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
eclipseaudio1530
2nd Generation Specific
5
04-01-2004 08:37 PM
jaidedeye
2nd Generation Specific
12
03-18-2004 03:42 PM
Jims5543
ECU Discussions