What I need to do is piggy back the OMP circuit on a FD and see exactly what it does at different RPM's and loads. Is it simply RPM sensative or does load come into play?? If it is a simple RPM sensitive setup it should be easy. I just need to know exactly what kind of signal it is looking for.
Jims5543 is offline  
Old 01-14-2003, 09:56 PM
  #32  
Senior Member
 
13BAce's Avatar
 
Join Date: Nov 2001
Location: Bay Area, CA
Posts: 7,316
Default

Originally Posted by Jims5543' date='Jan 14 2003, 06:33 PM
What I need to do is piggy back the OMP circuit on a FD and see exactly what it does at different RPM's and loads. Is it simply RPM sensative or does load come into play?? If it is a simple RPM sensitive setup it should be easy. I just need to know exactly what kind of signal it is looking for.
You can adapt an 87-88 TII oil metering pump to the FD front cover. I know quite a few people who have done it.
13BAce is offline  
Old 01-15-2003, 11:18 AM
  #33  
Senior Member
 
j9fd3s's Avatar
 
Join Date: May 2002
Location: California
Posts: 22,465
Default

and on the 89+ fc they replace the omp rod holder with a spacer, so you can retro fit if you want to



mike
j9fd3s is offline  
Old 01-15-2003, 12:14 PM
  #34  
Senior Member
 
13BAce's Avatar
 
Join Date: Nov 2001
Location: Bay Area, CA
Posts: 7,316
Default

Originally Posted by j9fd3s' date='Jan 15 2003, 09:18 AM
and on the 89+ fc they replace the omp rod holder with a spacer, so you can retro fit if you want to



mike
I'm a fan of pre-mixing. The interior of the motor stays so clean without all of that sludge.
13BAce is offline  
Old 01-15-2003, 12:16 PM
  #35  
Super Moderator
 
vosko's Avatar
 
Join Date: Jul 2001
Location: NJ
Posts: 17,839
Default

Originally Posted by 13BAce' date='Jan 15 2003, 01:14 PM
[quote name='j9fd3s' date='Jan 15 2003, 09:18 AM'] and on the 89+ fc they replace the omp rod holder with a spacer, so you can retro fit if you want to



mike
I'm a fan of pre-mixing. The interior of the motor stays so clean without all of that sludge. [/quote]

i am running premix + the stock electronic OMP on my FD :bigok:
vosko is offline  
Old 01-15-2003, 01:13 PM
  #36  
Senior Member
Thread Starter
 
Jims5543's Avatar
 
Join Date: Dec 2001
Location: Jensen Beach, FL / Sylva, NC
Posts: 2,934
Default

Originally Posted by 13BAce' date='Jan 15 2003, 01:14 PM
[quote name='j9fd3s' date='Jan 15 2003, 09:18 AM'] and on the 89+ fc they replace the omp rod holder with a spacer, so you can retro fit if you want to



mike
I'm a fan of pre-mixing. The interior of the motor stays so clean without all of that sludge. [/quote]

I agree motor oil isnt really intended to be burned. If you look up a couple of posts you will see there is a devise that can give you the ability to run your pre-mix oil through your OMP. I have already made a 1 quart holding tank for this and as soon as I figure out the OMP signal I will be running the 2 cycle oil through the OMP.



Until then I will be premixing.
Jims5543 is offline  
Old 01-15-2003, 05:31 PM
  #37  
Senior Member
 
j9fd3s's Avatar
 
Join Date: May 2002
Location: California
Posts: 22,465
Default

you may want to email k2rd, he was thinking about making a metering pump control box, i know he knows how to do it, we just dont have a ginea pig



mike
j9fd3s is offline  
Old 01-15-2003, 09:45 PM
  #38  
Senior Member
Thread Starter
 
Jims5543's Avatar
 
Join Date: Dec 2001
Location: Jensen Beach, FL / Sylva, NC
Posts: 2,934
Default

Originally Posted by j9fd3s' date='Jan 15 2003, 06:31 PM
you may want to email k2rd, he was thinking about making a metering pump control box, i know he knows how to do it, we just dont have a ginea pig



mike
K2RD is this a member or a website?
Jims5543 is offline  
Old 01-15-2003, 09:54 PM
  #39  
Senior Member
 
13BAce's Avatar
 
Join Date: Nov 2001
Location: Bay Area, CA
Posts: 7,316
Default

Originally Posted by Jims5543' date='Jan 15 2003, 07:45 PM
[quote name='j9fd3s' date='Jan 15 2003, 06:31 PM'] you may want to email k2rd, he was thinking about making a metering pump control box, i know he knows how to do it, we just dont have a ginea pig



mike
K2RD is this a member or a website? [/quote]

http://www.k2rd.com
13BAce is offline  
Old 01-16-2003, 04:34 PM
  #40  
Senior Member
 
j9fd3s's Avatar
 
Join Date: May 2002
Location: California
Posts: 22,465
Default

thanks ace!



mike
j9fd3s is offline  