3rd Generation Specific Talk about 3rd gen RX-7's here.

Fd Guys Running External Fuel Pumps

Old Dec 8, 2003 | 05:31 PM
  #1  
1Revvin7's Avatar
Thread Starter
Senior Member
 
Joined: Oct 2001
Posts: 10,906
From: Peoria, AZ
Default

Anyone here running an external pump without sumping the tank?

Nhra rules dicate you cannot modify the stock tank, and plus the FC has a sumped tank stock. So I was thinking of modifing the stock fuel pump assmebly by attaching an An- bung on top then maybe just a big pipe that ran down to the sump. Anyone want to tell me how they have theirs setup?
Old Dec 8, 2003 | 06:45 PM
  #2  
93 R1's Avatar
Senior Member
 
Joined: Sep 2002
Posts: 3,867
From: Maryland
Default

External pumps are LOUD! Go with twin intank units man.
Old Dec 8, 2003 | 07:10 PM
  #3  
1Revvin7's Avatar
Thread Starter
Senior Member
 
Joined: Oct 2001
Posts: 10,906
From: Peoria, AZ
Default

I am still debating, I like Tyson's setup. Might just go pickup another couple walbros..
Old Dec 8, 2003 | 07:14 PM
  #4  
9BASE3's Avatar
Senior Member
 
Joined: Feb 2002
Posts: 6,331
From: Frederick MD
Default

How do you guys wire 2 pumps? You can't just tap them together can you?
Old Dec 8, 2003 | 07:27 PM
  #5  
93 R1's Avatar
Senior Member
 
Joined: Sep 2002
Posts: 3,867
From: Maryland
Default

Pretty sure.



Whatever you do DO NOT get a weldon pump. SPEED-NYC had one. You could hear that **********er whine 50 ft away while his car was idling.
Old Dec 8, 2003 | 07:34 PM
  #6  
9BASE3's Avatar
Senior Member
 
Joined: Feb 2002
Posts: 6,331
From: Frederick MD
Default

I think I'll just do a dual Walboro for starters.. There is quite a few people running them. Just gotta get to the parts store so I can start fabbing...



Justin, is that a "yes" for wiring the pumps together? I can't really see why you couldn't... Unless the current draw is too much for the gauge of wire...
Old Dec 8, 2003 | 08:03 PM
  #7  
TYSON's Avatar
Senior Member
 
Joined: Jan 2003
Posts: 2,871
From: London, Ontario
Default

Supra pumps each draw 12 amps at 40 psi. That's too much for the stock circuit with 2 of them.



Quick and dirty way would be to have a 40 amp fuse and relay run directly from the battery and use the stock fuel pump wires turn on that relay.
Old Dec 8, 2003 | 08:13 PM
  #8  
9BASE3's Avatar
Senior Member
 
Joined: Feb 2002
Posts: 6,331
From: Frederick MD
Default

Originally Posted by TYSON' date='Dec 8 2003, 08:03 PM
Supra pumps each draw 12 amps at 40 psi. That's too much for the stock circuit with 2 of them.



Quick and dirty way would be to have a 40 amp fuse and relay run directly from the battery and use the stock fuel pump wires turn on that relay.
Sounds good to me. Any particular relay you would recommend? Sorry for all the questions, I just don't want to **** up a 6 month project with something silly.
Old Dec 8, 2003 | 08:36 PM
  #9  
1Revvin7's Avatar
Thread Starter
Senior Member
 
Joined: Oct 2001
Posts: 10,906
From: Peoria, AZ
Default

How can I make sure the walrbo that a walrbo is a 255lpg high pressure unit?? I've heard of the ebay ones being a lower pressure unit... I don't want to get myself into 9base3's situation..
Old Dec 8, 2003 | 08:38 PM
  #10  
TYSON's Avatar
Senior Member
 
Joined: Jan 2003
Posts: 2,871
From: London, Ontario
Default

I think my 40 amp came from an NX kit, but I used that for my fans.



I actually have 2 20 amp relays. One is the standard that came with my Haltech, the other is an auto parts store special being controlled by the auxillary pump output on the Haltech.



I've improved my pump design greatly in my head, but I refuse to spend any more money there unless I absolutely have to.



Or if at least 5 people wanted the most PIMP fuel pump setup ever!!

Thread Tools
Search this Thread

All times are GMT -5. The time now is 04:41 PM.