2nd Generation Specific 1986-1992 Discussion

where is the engine to firewall ground at?

Thread Tools
 
Search this Thread
 
Old Nov 19, 2010 | 08:27 AM
  #1  
91turbo2's Avatar
Thread Starter
Junior Member
 
Joined: Nov 2010
Posts: 12
From: Nashville,Tenessee
Default

im trying to find the engine to firewall ground and cant find it where should it be?
Old Nov 19, 2010 | 09:21 AM
  #2  
Baldy's Avatar
Super Moderator
 
Joined: Sep 2002
Posts: 5,425
From: Tallahassee, FL
Default

Not sure on the TII, but on the N/A there's a ground from where the tranny bellhousing meets the engine, to the firewall.
Old Nov 19, 2010 | 10:35 AM
  #3  
fc3sboy1's Avatar
Senior Member
 
Joined: May 2003
Posts: 1,331
From: watertown wisconsin
Default

there is a bolt hole on the top of the bell housing wich where the wire bolts to, the other end is on the fire wall and is a male spade terminal that is bolted to the right of the wiper motor but not qhuit center of the fire wall. if you are missing the wire all together just make up a new one with heavy 08 or 04 guage wire with eyelets on either end and just find a spot on the fire wall to bolt it to and one on the bell housing or somplace on the engine, it really does not matter but i like to use the center hole on the center iron where there used to be an egr on the s4 motors but on the s5 and 6 there is just a flat area but the holes are still there and threaded.



randy
Old Nov 19, 2010 | 11:40 AM
  #4  
91turbo2's Avatar
Thread Starter
Junior Member
 
Joined: Nov 2010
Posts: 12
From: Nashville,Tenessee
Default

Originally Posted by fc3sboy1
there is a bolt hole on the top of the bell housing wich where the wire bolts to, the other end is on the fire wall and is a male spade terminal that is bolted to the right of the wiper motor but not qhuit center of the fire wall. if you are missing the wire all together just make up a new one with heavy 08 or 04 guage wire with eyelets on either end and just find a spot on the fire wall to bolt it to and one on the bell housing or somplace on the engine, it really does not matter but i like to use the center hole on the center iron where there used to be an egr on the s4 motors but on the s5 and 6 there is just a flat area but the holes are still there and threaded.



randy


thanks ill check it out,could a bad engine to firewall ground cause the car not to start?..or even not run right?..(im new to rotary motors)
Old Nov 19, 2010 | 12:09 PM
  #5  
fc3sboy1's Avatar
Senior Member
 
Joined: May 2003
Posts: 1,331
From: watertown wisconsin
Default

it is posible yes but there is also a ground that bolts in the threw bolt for the starter that is direct off the battery. you need both. i saw a car weld its injectors due to someone not having the grounds on the motor because he was in too much of a hurry to hear the motor run and fire it up before the wiring was finished. there is also a picture floating around nopistons about the tack needle center point melting due to lack of firewall ground
Old Nov 19, 2010 | 02:30 PM
  #6  
RX7 13B 4 UR AZZ's Avatar
Senior Member
 
Joined: Feb 2003
Posts: 1,591
From: Miami, Florida
Default

I learned the hard way to make sure all grounds are good when i set my stainless steel clutch line on fire because the ground for the starter was not hooked up. it was a beautiful mess of things LOL.
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
stuwk
RX-7 & RX-8 Parts For Sale & Wanted
0
Jul 10, 2015 07:17 PM
jebenkurac
3rd Generation Specific
1
Aug 22, 2006 06:21 AM
apexkw
3rd Generation Specific
8
Jul 14, 2006 07:07 PM
glennsseven
2nd Generation Specific
4
Mar 14, 2006 03:52 PM
christi
Insert BS here
8
Sep 11, 2002 12:40 AM

Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 



All times are GMT -5. The time now is 04:07 PM.