Holy Smokes (omp Question)!

Thread Tools
 
Search this Thread
 
Old 06-20-2004, 10:19 AM
  #11  
Senior Member
 
Fd3BOOST's Avatar
 
Join Date: Jun 2002
Location: La Plata, Maryland
Posts: 9,725
Default

Originally Posted by boost_this' date='Jun 20 2004, 07:13 AM
thanks for the pic, I wasn't sure if simply disconnecting the OMP electically would disable oil delivery...I will give it a try.



I may take you up on the fans just to trouble shoot whats up with my set up (when would be a good time to pick up?). I find it hard to believe both fan motors burnt out at the same time... I was able to verify it wasn't my sensor connection since grounding activated the fan relay...just no action at the fans..arrgh.



Thanks again,



Chris
Well if disconnecting it doesn't do it then nothing will short of removing it entirely. Did k2rd send you the block off for it? Anyway I got to run around today and BBQ at my folks tonight but I will set the fans on the front porch for you. Come by for them whenever you like.
Fd3BOOST is offline  
Old 06-20-2004, 10:28 AM
  #12  
Member
Thread Starter
 
boost_this's Avatar
 
Join Date: Apr 2004
Posts: 44
Question

Dave thanks again, I owe you big time!



Arrgh, I just looked at my OMP connection and it was only half-way in!!!! This damn thing could have been running during initial break in without any OMP at all and no premix!!!!!!!!!!!!!



I wonder how long it takes to trash a motor without OMP running or am I just being way too paranoid?? Motor has maybe 30 mins total run time.



Chris
boost_this is offline  
Old 06-20-2004, 10:32 AM
  #13  
Senior Member
 
j9fd3s's Avatar
 
Join Date: May 2002
Location: California
Posts: 22,465
Default

Originally Posted by boost_this' date='Jun 20 2004, 07:28 AM
Dave thanks again, I owe you big time!



Arrgh, I just looked at my OMP connection and it was only half-way in!!!! This damn thing could have been running during initial break in without any OMP at all and no premix!!!!!!!!!!!!!



I wonder how long it takes to trash a motor without OMP running or am I just being way too paranoid?? Motor has maybe 30 mins total run time.



Chris
you have a power fc? the power fc doesnt care if the metering pump is plugged in or not, be nice if it told you.



it takes hours to kill the motor with no metering pump
j9fd3s is offline  
Old 06-20-2004, 10:36 AM
  #14  
Senior Member
 
Fd3BOOST's Avatar
 
Join Date: Jun 2002
Location: La Plata, Maryland
Posts: 9,725
Default

Yea Chris, these rotaries are way stronger than you think.



Mike, he is using a purple box.
Fd3BOOST is offline  
Old 06-20-2004, 10:53 AM
  #15  
Senior Member
 
j9fd3s's Avatar
 
Join Date: May 2002
Location: California
Posts: 22,465
Default

Originally Posted by Fd3BOOST' date='Jun 20 2004, 07:36 AM
Yea Chris, these rotaries are way stronger than you think.



Mike, he is using a purple box.
hmm it should have freaked out? any other codes?
j9fd3s is offline  
Old 06-20-2004, 11:04 AM
  #16  
Senior Member
 
83turbo's Avatar
 
Join Date: Nov 2003
Posts: 480
Default

I would suspect that with the connector off, the pump would simply

stay at the last position - it would still pump. It looks like the

electronic pump just uses a stepper to adjust the stroke, and a pot

to sense where the stroke currently is.
83turbo is offline  
Old 06-20-2004, 11:43 AM
  #17  
Member
Thread Starter
 
boost_this's Avatar
 
Join Date: Apr 2004
Posts: 44
Default

Again, thanks for the sanity check! I connected the OMP and saw no difference in the smoke. Guess I need to stop freaking out and take things one step at a time.



I am going to focus on the fans and getting the battery permanently mounted so I can take it out on the road. I will stop by to pick up the fans in a few mins Dave.



Thanks,



Chris
boost_this is offline  
Old 06-20-2004, 11:46 AM
  #18  
Member
Thread Starter
 
boost_this's Avatar
 
Join Date: Apr 2004
Posts: 44
Default

No codes set on the PFS but I see check engine light comes on after initial start up... need to figure out how to pull the codes so I can see what the prob is.



Chris
boost_this is offline  
Old 06-20-2004, 11:53 AM
  #19  
Senior Member
 
heretic's Avatar
 
Join Date: Jun 2004
Posts: 524
Default

Originally Posted by j9fd3s' date='Jun 20 2004, 07:32 AM
it takes hours to kill the motor with no metering pump
Years, really. There are some "rotary gurus" near my area who remove the OMP altogether, no premix. It just wears the engine out faster. All the unburned gasoline at the ends of the chamber does provide some lubricity, albeit not as good as oil will do.



Not recommended for running under boost or high RPM for extended periods of time!
heretic is offline  
Old 06-20-2004, 12:48 PM
  #20  
Member
Thread Starter
 
boost_this's Avatar
 
Join Date: Apr 2004
Posts: 44
Default

Well took it down the road again, and the smoke was just way too much to take it any further... pulled it back in and realized I had quite a bit of smoke coming up into the engine bay from the turbo/exhaust manifold area as well.....looked underneath and there is quite a bit of oil dripping out of the exhaust sides of the turbos....I see it also dripping from the connection between the DP and Cat so alot of oil is being pumped into the exhaust being burnt in the DP/CAT.... now the question is...is it coming from the turbo (bad seal on the exhaust side? or the from the motor? I pulled the IC/Intake tract and its bone dry so I am confident its not leaking turbo oil being sucked into the motor. I am going to pull the plugs again to try and determine if its burning in the engine or not...but looks like either way I will be pulling the turbos off unless I can verify the OMP is pumping it in. Arrrgh.



Chris
boost_this is offline  