3rd Generation Specific Talk about 3rd gen RX-7's here.

Fuel Pressure Problem! Any Ideas

Thread Tools
 
Search this Thread
 
Old 09-08-2005, 11:07 PM
  #1  
Senior Member
Thread Starter
 
FikseRxSeven's Avatar
 
Join Date: Jan 2003
Location: union, new jersey
Posts: 8,079
Default

so... i cant get my fuel pressure lower than 62psi at 12v and cant get it lower than 69psi when the car is running and im getting 14v





the story.



i noticed that my fuel system was not holding pressure when the car is off, and i wasnt getting proper fuel pressure. so i decide to check out the tank. found that i had a crack in one of the lines, replaced both of them with high pressure fuel hoses (easy enough). now when i turned the car on, my fuel pressure skyrocketted!!!! i had to get to work soon, so i let the car run for 15 mins to make sure everythign will be fine, and everything was fine til then.



when i got to work, i noticed a fuel smell and then saw gas dripping from around the firewall/transmission area. so went into work and let things cool down. when i left work, i checked the pressure from just the battery, and it was still at 62psi. i then screwed the FPR adjuster in, and as the fuel pressure hit 70psi, i hear a hissing sound and fuel started dripping again. i then lowered the fuel pressure and it stopped.



to make the drive home, i disconnected the power to 1 of the fuel pumps. with 1 walbro 255, my fuel pressure was good at 40psi. drove home with no gas smell.



i have yet to determine whether the leak is coming from the feed side or the return side of the fuel pressure regulator, judging by the location of the dripping fuel, its the return line,



my setup right now are 2 fuel pumps, each feeding the primary and secondary rails, the lines meet at an FPR and returns to the stock return line. so 3/8" hoses(and metal lines) and -6an lines and fittings from the firewall. right now i have an xs fpr on there, im gunna try another fpr to rule that out.



just on a side note... rfreeman is running the same setup and is getting 40psi.



martin
FikseRxSeven is offline  
Old 09-08-2005, 11:11 PM
  #2  
Administrator
 
phinsup's Avatar
 
Join Date: Jul 2001
Location: Stuart, FL
Posts: 24,416
Default

fpr **** maybe?
phinsup is offline  
Old 09-08-2005, 11:21 PM
  #3  
Senior Member
 
94touring's Avatar
 
Join Date: Jul 2001
Location: Tulsa, OK
Posts: 3,346
Default

Take a look at the fuel pulsation dampener too. I had one go bad and leak fuel.
94touring is offline  
Old 09-08-2005, 11:31 PM
  #4  
Senior Member
Thread Starter
 
FikseRxSeven's Avatar
 
Join Date: Jan 2003
Location: union, new jersey
Posts: 8,079
Default

i dont have a fuel pulsation dampener, both my primary and secondary rails are aftermarket with topfeed injectors.... maybe bad o rings? ill have to check tomorrow
FikseRxSeven is offline  
Old 09-09-2005, 01:33 AM
  #5  
Senior Member
Thread Starter
 
FikseRxSeven's Avatar
 
Join Date: Jan 2003
Location: union, new jersey
Posts: 8,079
Default

a thought came to my mind.... what if any of the emissions stuff was accdentally forgotten by the tank... i assume that would cause a restriction right?



i remember seeing something that resembled a check valve (white with green) around the fuel tank area when i openned it up earlier
FikseRxSeven is offline  
Old 09-09-2005, 10:28 AM
  #6  
Junior Member
 
Buzzn2's Avatar
 
Join Date: Aug 2004
Location: THE COUVE
Posts: 16
Default

Usually not a problem, what pump and regulator are you running?



Chris@gtgarage.com





[quote name='FikseRxSeven' date='Sep 8 2005, 11:33 PM']a thought came to my mind.... what if any of the emissions stuff was accdentally forgotten by the tank... i assume that would cause a restriction right?



i remember seeing something that resembled a check valve (white with green) around the fuel tank area when i openned it up earlier

[snapback]756690[/snapback]

[/quote]
Buzzn2 is offline  
Old 09-09-2005, 01:21 PM
  #7  
Senior Member
Thread Starter
 
FikseRxSeven's Avatar
 
Join Date: Jan 2003
Location: union, new jersey
Posts: 8,079
Default

i have 2 walbro 255lph and an xs engineering regulator
FikseRxSeven is offline  
Old 09-09-2005, 05:32 PM
  #8  
Senior Member
 
rfreeman27's Avatar
 
Join Date: Dec 2002
Location: fredneck MD
Posts: 4,107
Default

get another regulator. Verify that your return line goes straight back into the tank withno kinks.
rfreeman27 is offline  
Old 09-11-2005, 09:55 AM
  #9  
Senior Member
 
djgiantrobot's Avatar
 
Join Date: Oct 2002
Posts: 1,019
Default

sounds like restriction in the return line ^^^^^^^^^^^
djgiantrobot is offline  
Old 09-11-2005, 09:55 AM
  #10  
Junior Member
 
Buzzn2's Avatar
 
Join Date: Aug 2004
Location: THE COUVE
Posts: 16
Default

Its the Walbro pump they are unreliabl, noisy, and have drain back problems , Use OEM twin turbo supra pump, Itl supply min. enough for about 450 wheel hp









[quote name='rfreeman27' date='Sep 9 2005, 03:32 PM']get another regulator. Verify that your return line goes straight back into the tank withno kinks.

[snapback]756961[/snapback]

[/quote]
Buzzn2 is offline  


Quick Reply: Fuel Pressure Problem! Any Ideas



All times are GMT -5. The time now is 10:16 AM.