2nd Generation Specific 1986-1992 Discussion

its electrical/fuel

Thread Tools
 
Search this Thread
 
Old Jan 12, 2009 | 02:06 PM
  #1  
turbo-1eleven's Avatar
Thread Starter
Junior Member
 
Joined: Jan 2009
Posts: 2
Default

the injectors are wired right

fuel pump works

the fuel pump is new(verified 2day)

fuel pump relay is good

main relay is good

the afm is hooked up

all vacuums are accounted for

all plugz are pluged

im getting fuel in the lines to the injectors



the car still starts goes up high in idel to about 3k starts falling and then dies. if i keep my foot on the gas during start up it will run about 20 secs. if i start and then take my foot off about 7 secs and patting the gas judt kills it faster.



now i have theory,

my gas gauge does not read, so i took the fuel pump out to check (hince the new fuel pump verification) and almost a full tank. so what controls the gas gauge ? the floater is working and in good shape, is there a fuse, relay, fuseable link, anything for the gauge could that also may control the fuel flow.



its almost as if the car starts but when it fires the injectors stop working. is there a certain fuse or relay just for injectors? i checked my egi fuse and it is still good as far as that goes i just have no more ideas. one thing i did find was a few vac leaks on the air intake, but they are taken care of now.



wits end now

FC= F@#KING COMPLICATED
Old Jan 12, 2009 | 06:12 PM
  #2  
mazdaspeed7's Avatar
Super Moderator
 
Joined: Sep 2002
Posts: 2,763
From: Savannah, Ga
Default

Sounds like you still have vacuum leaks.
Old Jan 12, 2009 | 09:49 PM
  #3  
RE_TurboFB's Avatar
Senior Member
 
Joined: Dec 2005
Posts: 407
From: Oregon
Default

Sounds kinda like the "Fuel pressure regulator control solenoid" is hooked up wrong... Your issue sounds like a fuel problem for sure!!



I built a engine and forgot to hook up the fuel pressure regulator control solenoid. It would start jump up to like 2500 RPM's and then just die.. It would help the car run a bit longer if I pump the gas a bunch..



I hooked up the vacuum lines and pluged in the connector, Then bam it fired right up and idled...



I have had engines that would still run even with horrible vacuum leaks..
Old Jan 13, 2009 | 05:02 PM
  #4  
RONIN FC's Avatar
Senior Member
 
Joined: Oct 2003
Posts: 1,420
From: Boston Ma.
Default

Fuel relay could be powering the fuel pump only on startup but not in the run position. Yellow and black relay near the steering column.



Temporarily re-wire it directly to be sure, so you KNOW the pump is running.
Old Jan 17, 2009 | 05:26 AM
  #5  
RicerJ's Avatar
Senior Member
 
Joined: Dec 2008
Posts: 737
From: Folsom, CA
Default

or take your dash out and check to see if your connection to your cluster is tight it might be loose or disconnected and thats why your gauge isnt working
Old Jan 20, 2009 | 08:46 AM
  #6  
cembrent's Avatar
Senior Member
 
Joined: Jul 2003
Posts: 105
From: Barrie, Ontario, Cananda
Default

I would just check the fuel pressure with a guage and go from there. As for the guage, just check it according to the fsm and it should be pretty easy to determine whether it's the sender or the guage. Usually tends to be the sender in my experience though.
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Fidelity101
2nd Generation Specific
0
May 18, 2006 06:46 PM
j9fd3s
Insert BS here
14
Jan 12, 2006 11:56 AM
FrostRacing
2nd Generation Specific
7
Dec 15, 2003 01:07 AM
94touring
3rd Generation Specific
6
Jan 23, 2003 01:46 PM
vosko
Insert BS here
14
Dec 19, 2001 07:31 AM

Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 



All times are GMT -5. The time now is 06:03 AM.